Italy Chair : 1 unit
Italy Operation Light: 1 set
New Side Box: 1 set
Three way syringe: 1 set
Suction center system: 1 set
Heater: 1 set
Foot control for the operation light: 1 set
Foot controller: 1 set
|
Features: Lead: Standard 12 leads Acquisition: Simultaneous 12 leads Resolution: 12bit/1000Hz Operation mode: Manual/Auto/Analysis Modes Filter: AC.EMG Filter Drift filter: Anti-Drift System CMRR: ≥100dB, with AC Filter Input circuit: Floating, Protection against defibrillator effect Input circuit current: ≤0.1µA Drift filter: Anti-Drift System CMRR: ≥100dB, with AC Filter Input circuit: Floating, Protection against defibrillator effect Input circuit current: ≤0.1µA Input Impedance: >50MΩ Patient current leakage: <10µA Calibrating voltage: 1mV±3% Voltage tolerance: ±500mV Time constant: >3.2s Frequent response: 0.05Hz~160Hz Noise level: ≤15µVp-p Threshold: ≤20µV Paper speed: 25, 50mm/s (±3%) Sensitivity: Auto, 2.5, 5, 10, 20, 40mm/mV Recorder: High resolution thermal printer Safety standard: GB9706.1-2007, IEC Class I, Type CF Specifications:
|
Portable 6 channel ECG machine |
Manual/Auto/Arrhythmia Analysis Modes |
112mm 3/6 channel format recording |
Built in rechargable Li-Ion battery 14.4V (2200mAh) |
Adapt to 110-230V, 50/60HZ AC power supply |
Real-time ECG waveform, cases save/replay |
Built in USB/RS232 interface (ECGNET software optional) |
Package: 40cm×34cm×22cm GW: 4.6KG NW: 1.7KG |
320×240 graphic 5.7inch LCD, 16cases save/replay |
Features: Lead: Standard 12 leads Acquisition: Simultaneous 12 leads Resolution: 12bit/1000Hz Operation mode: Manual/Auto/Analysis Modes Filter: AC.EMG Filter Drift filter: Anti-Drift System CMRR: ≥100dB, with AC Filter Input circuit: Floating, Protection against defibrillator effect Input circuit current: ≤0.1µA Drift filter: Anti-Drift System CMRR: ≥100dB, with AC Filter Input circuit: Floating, Protection against defibrillator effect Input circuit current: ≤0.1µA Input Impedance: >50MΩ Patient current leakage: <10µA Calibrating voltage: 1mV±3% Voltage tolerance: ±500mV Time constant: >3.2s Frequent response: 0.05Hz~160Hz Noise level: ≤15µVp-p Threshold: ≤20µV Paper speed: 25, 50mm/s (±3%) Sensitivity: Auto, 2.5, 5, 10, 20, 40mm/mV Recorder: High resolution thermal printer Safety standard: GB9706.1-2007, IEC Class I, Type CF Specifications:
|
Features: Lead: Standard 12 leads Acquisition: Simultaneous 12 leads Resolution: 12bit/1000Hz Operation mode: Manual/Auto/Analysis Modes Filter: AC.EMG Filter Drift filter: Anti-Drift System CMRR: ≥100dB, with AC Filter Input circuit: Floating, Protection against defibrillator effect Input circuit current: ≤0.1µA Drift filter: Anti-Drift System CMRR: ≥100dB, with AC Filter Input circuit: Floating, Protection against defibrillator effect Input circuit current: ≤0.1µA Input Impedance: >50MΩ Patient current leakage: <10µA Calibrating voltage: 1mV±3% Voltage tolerance: ±500mV Time constant: >3.2s Frequent response: 0.05Hz~160Hz Noise level: ≤15µVp-p Threshold: ≤20µV Paper speed: 25, 50mm/s (±3%) Sensitivity: Auto, 2.5, 5, 10, 20, 40mm/mV Recorder: High resolution thermal printer Safety standard: GB9706.1-2007, IEC Class I, Type CF Specifications: |
Breath Rate | 10 15 20 25 30 35bpm |
I:E | 2:1 1:1 1:1.5 1:2 1:2.5 1:3 |
Tidal Volume | 300 ~ 1000 ml |
W×D×H | 380×120×240mm |
Weight | 3kg |
AC Voltage | 110V~240V |
DC Voltage | 12V |
Inlet Battery | 12V , 2Ah |
Compact and portable, allowing for uninterrupted monitoring with built-in battery | |
High bright LEDS display of NIBP, SPO2 and pulse rate | |
High resolutioncolor LCD for trend tabular and SPO2 waveforms display | |
Manual/auto/continuous measurement of NIBP | |
Adjustable audible and visual alarms | |
Up to 600 groups NIBP data up to 10 hours | |
Suitable for adult, pediatric and neonatal patient | |
Display | 7 segment LEDS for systolic, diastolic, mean pressures, SPO2 and pulse rate |
2.4``color LCD for waveforms, bargraphic, trend and aystem menu | |
NIBP | Method: Oscillometry |
Operation modes: Manual/Automatic/STAT | |
Auto Measure time : 5~250 minutes adjustable, interval 5 minutes | |
Measurement range: 10~270mmHg | |
Overpressure protection: yes | |
Resolution: 1mmHg | |
Alarm: systolic, Diastolic, Mean | |
SPO2 | Measurement range: 0~100% |
Resolution: 1% | |
Accuracy: 70~100% ±2%, 0~69% unspecified | |
Alarm range: 0~100% | |
Pulse Rate | Range: 0~254bpm |
Resolution: 1bpm | |
Accuracy: ±1bpm | |
Dimension: 200*230*75mm | |
Weight: about 3.5kg | |
Power supply: AC 100~250V 50/60Hz |