Kamis, 02 Agustus 2012

DC3600 Dental Unit

DC3600 Dental Unit



Italy Chair : 1 unit
Italy Operation Light: 1 set
New Side Box: 1 set
Three way syringe: 1 set
Suction center system: 1 set
Heater: 1 set 
Foot control for the operation light: 1 set
Foot controller: 1 set

DC1000 Dental Chair

DC1000 Dental Chair







Features and Standard configuration:
All controlled by the electric valve 
Plastic pipe 
DC motor 
Air spring 
Air-lock balance arm system 
3 way Syringe (one for hot and one for cold), 2pcs 
Water Suction and Saliva Ejector,1set each 
The device for prevent refluence and the Built-in Water purified System 
Automatic Heating water system 
Operation Light 
DC X-film viewer 
Display System of the H.P.’s air pressure 
Dentist Stool,1pc








ECG-300G Digital Three Channel ECG

ECG-300G Digital Three Channel ECG






Features
High resolution thermal printing system, high precision
12 leads collection in phase as well as 3 leads printing in phase
Digital design and filter, baseline auto-adjustable.
LCD displays operation menu .DC/AC auto-exchange
Automatic measurement, analysis and diagnosis with high speed
Elegant and compact outlook, with inner handhold.




ECG-120 Digital Electrocardiograph

ECG-120 Digital Electrocardiograph








Features:
Lead: Standard 12 leads
Acquisition: Simultaneous 12 leads
Resolution: 12bit/1000Hz
Operation mode: Manual/Auto/Analysis Modes
Filter: AC.EMG Filter
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Input Impedance: >50MΩ
Patient current leakage: <10µA
Calibrating voltage: 1mV±3%
Voltage tolerance: ±500mV
Time constant: >3.2s
Frequent response: 0.05Hz~160Hz
Noise level: ≤15µVp-p
Threshold: ≤20µV
Paper speed: 25, 50mm/s (±3%)
Sensitivity: Auto, 2.5, 5, 10, 20, 40mm/mV
Recorder: High resolution thermal printer
Safety standard: GB9706.1-2007, IEC Class I, Type CF
Specifications:
Portable 12 channel ECG machine
Manual/Auto/Arrhythmia Analysis Modes
Alphabetic keyboard for patient information
Built in rechargable Li-Ion battery 14.4V (4400mAh)
Adapt to 110-230V, 50/60HZ AC power supply
Real-time ECG waveform, cases save/replay
Built in USB/RS232 interface (ECGNET software optional)
Package: 40cm×34cm×22cm   GW: 5.9KG   NW: 3.2KG
320×240 graphic 5.7inch LCD, 16cases save/replay

ECG-602 Digital Electrocardiograph

ECG-602 Digital Electrocardiograph









Features:
Lead: Standard 12 leads
Acquisition: Simultaneous 12 leads
Resolution: 12bit/1000Hz
Operation mode: Manual/Auto/Analysis Modes
Filter: AC.EMG Filter
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Input Impedance: >50MΩ
Patient current leakage: <10µA
Calibrating voltage: 1mV±3%
Voltage tolerance: ±500mV
Time constant: >3.2s
Frequent response: 0.05Hz~160Hz
Noise level: ≤15µVp-p
Threshold: ≤20µV
Paper speed: 25, 50mm/s (±3%)
Sensitivity: Auto, 2.5, 5, 10, 20, 40mm/mV
Recorder: High resolution thermal printer
Safety standard: GB9706.1-2007, IEC Class I, Type CF
Specifications:
Portable 6 channel ECG machine
Manual/Auto/Arrhythmia Analysis Modes
112mm 3/6 channel format recording
Built in rechargable Li-Ion battery 14.4V (2200mAh)
Adapt to 110-230V, 50/60HZ AC power supply
Real-time ECG waveform, cases save/replay
Built in USB/RS232 interface (ECGNET software optional)
Package: 40cm×34cm×22cm   GW: 4.6KG   NW: 1.7KG
320×240 graphic 5.7inch LCD, 16cases save/replay

ECG-601 Digital Electrocardiograph

ECG-601 Digital Electrocardiograph







Features:
Lead: Standard 12 leads
Acquisition: Simultaneous 12 leads
Resolution: 12bit/1000Hz
Operation mode: Manual/Auto/Analysis Modes
Filter: AC.EMG Filter
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Input Impedance: >50MΩ
Patient current leakage: <10µA
Calibrating voltage: 1mV±3%
Voltage tolerance: ±500mV
Time constant: >3.2s
Frequent response: 0.05Hz~160Hz
Noise level: ≤15µVp-p
Threshold: ≤20µV
Paper speed: 25, 50mm/s (±3%)
Sensitivity: Auto, 2.5, 5, 10, 20, 40mm/mV
Recorder: High resolution thermal printer
Safety standard: GB9706.1-2007, IEC Class I, Type CF
Specifications:

Portable 6 channel ECG machine
Manual/Auto/Arrhythmia Analysis Modes
112mm 3/6 channel format recording
Built in rechargable Li-Ion battery 14.4V (2200mAh)
Adapt to 110-230V, 50/60HZ AC power supply
Real-time ECG waveform, cases save/replay
Built in USB/RS232 interface (ECGNET software optional)
Package: 40cm×34cm×22cm   GW: 4.6KG   NW: 1.7KG
320×240 graphic 3.8 inch LCD

Rabu, 01 Agustus 2012

ECG-302 Digital Electrocardiograph

ECG-302 Digital Electrocardiograph




Features:
Lead: Standard 12 leads
Acquisition: Simultaneous 12 leads
Resolution: 12bit/1000Hz
Operation mode: Manual/Auto/Analysis Modes
Filter: AC.EMG Filter
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Input Impedance: >50MΩ
Patient current leakage: <10µA
Calibrating voltage: 1mV±3%
Voltage tolerance: ±500mV
Time constant: >3.2s
Frequent response: 0.05Hz~160Hz
Noise level: ≤15µVp-p
Threshold: ≤20µV
Paper speed: 25, 50mm/s (±3%)
Sensitivity: Auto, 2.5, 5, 10, 20, 40mm/mV
Recorder: High resolution thermal printer
Safety standard: GB9706.1-2007, IEC Class I, Type CF
Specifications:
3 channel ECG machine with measurement
Manual/Auto/Arrhythmia Analysis Modes
80mm 3-ch recording with rhythm lead
Built in rechargable Li-Ion battery 14.4V (2200mAh)
Adapt to 110-230V, 50/60HZ AC power supply
Real-time ECG waveform, cases save/replay
Built in USB/RS232 interface (ECGNET software optional)
Package: 40cm×34cm×22cm   GW: 4.6KG   NW: 1.7KG
320×240 graphic 5.7inch LCD, 16cases save/replay

ECG-301 Digital Electrocardiograph

ECG-301 Digital Electrocardiograph





Features:
Lead: Standard 12 leads
Acquisition: Simultaneous 12 leads
Resolution: 12bit/1000Hz
Operation mode: Manual/Auto/Analysis Modes
Filter: AC.EMG Filter
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Input Impedance: >50MΩ
Patient current leakage: <10µA
Calibrating voltage: 1mV±3%
Voltage tolerance: ±500mV
Time constant: >3.2s
Frequent response: 0.05Hz~160Hz
Noise level: ≤15µVp-p
Threshold: ≤20µV
Paper speed: 25, 50mm/s (±3%)
Sensitivity: Auto, 2.5, 5, 10, 20, 40mm/mV
Recorder: High resolution thermal printer
Safety standard: GB9706.1-2007, IEC Class I, Type CF
Specifications:

3 channel ECG machine with measurement
Manual/Auto/Arrhythmia Analysis Modes
80mm 3-ch recording with rhythm lead
Built in rechargable Li-Ion battery 14.4V (2200mAh)
Adapt to 110-230V, 50/60HZ AC power supply
Real-time ECG waveform, cases save/replay
Built in USB/RS232 interface (ECGNET software optional)
Package: 40cm×34cm×22cm   GW: 4.6KG   NW: 1.7KG
320×240 graphic 3.8 inch LCD

ECG-102 Digital Electrocardiograph

ECG-102 Digital Electrocardiograph







Features:
Lead: Standard 12 leads
Acquisition: Simultaneous 12 leads
Resolution: 12bit/1000Hz
Operation mode: Manual/Auto/Analysis Modes
Filter: AC.EMG Filter
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Input Impedance: >50MΩ
Patient current leakage: <10µA
Calibrating voltage: 1mV±3%
Voltage tolerance: ±500mV
Time constant: >3.2s
Frequent response: 0.05Hz~160Hz
Noise level: ≤15µVp-p
Threshold: ≤20µV
Paper speed: 25, 50mm/s (±3%)
Sensitivity: Auto, 2.5, 5, 10, 20, 40mm/mV
Recorder: High resolution thermal printer
Safety standard: GB9706.1-2007, IEC Class I, Type CF
Specifications:

Single channel ECG machine with measurement
Manual/Auto/Arrhythmia Analysis Modes
Built in rechargable NI-MH battery 12V (1500mAh)
Adapt to 110-230V, 50/60HZ AC power supply
Built in USB/RS232 interface (ECGNET software optional)
ECG waveform, 16 cases save/replay
Package: 40cm×34cm×22cm   GW: 4.6KG   NW: 1.7KG
320×240 graphic 3.8inch LCD, 16cases save/replay

ECG-101 Digital Electrocardiograph



ECG-101 Digital Electrocardiograph




Features:
Lead: Standard 12 leads
Acquisition: Simultaneous 12 leads
Resolution: 12bit/1000Hz
Operation mode: Manual/Auto/Analysis Modes
Filter: AC.EMG Filter
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Drift filter: Anti-Drift System
CMRR: ≥100dB, with AC Filter
Input circuit: Floating, Protection against defibrillator effect
Input circuit current: ≤0.1µA
Input Impedance: >50MΩ
Patient current leakage: <10µA
Calibrating voltage: 1mV±3%
Voltage tolerance: ±500mV
Time constant: >3.2s
Frequent response: 0.05Hz~160Hz
Noise level: ≤15µVp-p
Threshold: ≤20µV
Paper speed: 25, 50mm/s (±3%)
Sensitivity: Auto, 2.5, 5, 10, 20, 40mm/mV
Recorder: High resolution thermal printer
Safety standard: GB9706.1-2007, IEC Class I, Type CF

Specification:

Single channel ECG machine with measurement
Manual/Auto/Arrhythmia Analysis Modes
Lead-off indicator
Built in rechargable NI-MH battery 12V (1500mAh)
Adapt to 110-230V, 50/60HZ AC power supply
Built in USB/RS232 interface (ECGNET software optional)
Package: 40cm×34cm×22cm   GW: 4.6KG   NW: 1.7KG
20×2 character LCD, USB is optional

PA-10 Portable Ventilator

PA-10 Portable Ventilator







Breath Rate10  15  20  25  30  35bpm
I:E2:1  1:1  1:1.5  1:2  1:2.5  1:3
Tidal Volume300 ~ 1000 ml
W×D×H380×120×240mm
Weight3kg
AC Voltage 110V~240V
DC Voltage12V
Inlet Battery12V , 2Ah



PDJ-2000 Vital Signs Monitor


 PDJ-2000 Vital Signs Monitor






  • Compact and portable, allowing for uninterrupted monitoring with built-in battery  
    High bright LEDS display of NIBP, SPO2 and pulse rate 
    High resolutioncolor LCD for trend tabular and SPO2 waveforms display 
    Manual/auto/continuous measurement of NIBP 
    Adjustable audible and visual alarms 
    Up to 600 groups NIBP data up to 10 hours 
    Suitable for adult, pediatric and neonatal patient 
    Display7 segment LEDS for systolic, diastolic, mean pressures, SPO2 and pulse rate 
    2.4``color LCD for waveforms, bargraphic, trend and aystem menu
    NIBPMethod: Oscillometry
    Operation modes: Manual/Automatic/STAT
    Auto Measure time : 5~250 minutes adjustable, interval 5 minutes 
    Measurement range: 10~270mmHg
    Overpressure protection: yes 
    Resolution: 1mmHg
    Alarm: systolic, Diastolic, Mean
    SPO2Measurement range: 0~100%
    Resolution: 1%
    Accuracy: 70~100% ±2%, 0~69% unspecified 
    Alarm range: 0~100%
    Pulse RateRange: 0~254bpm
    Resolution: 1bpm
    Accuracy: ±1bpm
    Dimension: 200*230*75mm
    Weight: about 3.5kg
    Power supply: AC 100~250V 50/60Hz